900 Memory - 8-Electrode Accuracy - 0.5μL Sample - Micro USB
VivaChek Ino Glucose Monitoring System delivers precise diabetes management through advanced 8-electrode test strips requiring only 0.5μL blood sample with results in 5 seconds. This compact meter stores 900 readings with averages, features ketone/hypo warnings, and supports PC data transfer for comprehensive glucose tracking.
8-electrode technology eliminates hematocrit (20-70%) and temperature interference
Micro 0.5μL sample minimizes discomfort with virtually painless testing
900 test memory with 7/14/30-day averages and time/date stamps
5 customizable test reminders promote consistent monitoring routine
Ketone & hypo warnings alert extreme glucose values (10-600 mg/dL range)
Micro-USB port enables fast data transfer to PC for healthcare review
Auto-coding with automatic strip recognition prevents calibration errors
2-minute auto-shutoff conserves battery life (1000+ tests per set)
| Parameter | Specification |
|---|---|
| Test Range | 10-600 mg/dL (0.6-33.3 mmol/L) |
| Sample Volume | 0.5μL capillary whole blood |
| Test Time | 5 seconds |
| Enzyme | Glucose Oxidase |
| Hematocrit | 20-70% |
| Operating Temp | 5°C - 45°C |
| Humidity | 10-90% RH |
| Battery | 2x coin batteries (1000+ tests) |
| Memory | 900 results with averages |
| Data Port | Micro USB |
When to Test:
Opening new test strip vial
Results don't match symptoms
Meter dropped or exposed to extremes
Before meals, bedtime, or as doctor advised
Testing Steps:
Insert test strip (auto-codes meter)
Apply blood sample to target end
Results display automatically in 5 seconds
Remove and eject strip hygienically
Perform Control Solution Test When:
New vial opened
Container left open
Results seem inaccurate
Meter dropped or overheated
Patient symptoms don't match readings
Meter Maintenance:
Clean weekly to remove fingerprints
Disinfect when blood contacts surface
Verify time/date before testing
Use backup meter method available
Store strips in original container at room temp
Close vial tightly after each strip use
Check expiration date before testing
Avoid bathroom/kitchen humidity storage
Repeat test if symptoms contradict results
Meter: 5-45°C, avoid direct sunlight
Strips: Room temperature, tightly sealed vial
Battery Life: Over 1000 tests per set
Strip Shelf Life: 24 months unopened (foil packs)
Q: How small is 0.5μL sample?
A: Smaller than pinhead - virtually painless fingerstick.
Q: What do warnings mean?
A: Ketone (>25 mmol/L) or Hypo (<70 mg/dL) alerts for immediate action.
Q: PC data transfer needed?
A: Essential for doctors tracking averages, trends, therapy adjustments.
Q: Strip compatibility?
A: Exclusive to VivaChek Ino system only.
Medical-grade 8-electrode accuracy eliminates common interferences
Minimal sample requirement improves daily compliance
Comprehensive memory and averaging supports therapy decisions
Hygienic strip handling reduces infection risk
Cost-effective professional monitoring solution